LHC RadMon SRAM Detectors Used at Different Voltages to Determine the Thermal Neutron to High Energy Hadron Fluence Ratio
38
Citations
13
References
2011
Year
Electrical EngineeringMemory ArchitectureEngineeringPhysicsNatural SciencesParticle PhysicsToshiba Sram MemoryNeutron SourceComputer EngineeringComputer ArchitectureCosmic RaySemiconductor MemoryMicroelectronicsNeutron ScatteringThermal NeutronLhc Radmon SystemMulti-channel Memory ArchitectureDifferent Voltages
The thermal neutron SEU cross-section of the Toshiba SRAM memory used in the LHC RadMon system was measured at different voltages. A method using the difference in its response compared to mixed particle energy field is proposed to be used as a discriminator between thermal neutron and high-energy hadron fluences. For test purposes, the proposed method was used at the CNGS and CERF facilities to estimate the field composition by counting SEUs at two different voltages and the results were compared to simulations.