Life tests on vacuum switches breaking 50 kA unidirectional current

I. Benfatto, A. De Lorenzi, Alvise Maschio, William Weigand, H.P. Timmert, H. Weyer

IEEE Transactions on Power Delivery · 1991 · 18 citations · 5 references

Concepts

Abstract

The results of two different series of life tests carried out on vacuum switches with a self-produced axial magnetic field (in view of their use in nuclear fusion facilities) are presented. The goal was to obtain a large number (on the order of 2000) of interruptions of a unidirectional current of over 50 kA, with a recovery voltage of up to 35 kV. A first series of tests showed that the test procedure with an accelerated life test was not adequate; it was also apparent that the contact plate, designed for 50 Hz applications, had weak points when subjected to extended thermal contacts. Therefore, a new version of the switches, with modified contacts, was built. Both versions of the switches were tested with a new test procedure, and satisfactory test results were obtained.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

5