Internal current probing of integrated circuits using magnetic force microscopy

A. N. Campbell, Edward I. Cole, Bruce A. Dodd, Richard E. Anderson

1993 · 13 citations · 12 references

Concepts

Abstract

A model for the magnetic force microscopy (MFM) imaging of IC currents is presented. MFM signal generation is described and the ability to analyze current direction and magnitude with a sensitivity of approximately 1 mA DC and approximately 1 mu A AC is demonstrated. Experimental results are a significant improvement over the 100 mA AC resolution previously reported using an electron beam to detect IC currents.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

12