IEEE Transactions on Magnetics · 2009 · 23 citations · 8 references
EngineeringMechatronics EngineeringInstrumentationRemote SensingSensorsAttitude DeterminationMagnetic SensorsSensor CalibrationCompass Error AnalysisCompass SensorsMagnetic Compass SystemsMagnetometers
<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> We discuss the origin of the crossfield sensitivity of AMR sensors, the way how this error may influence the performance of an AMR compass and methods for its correction. Finally, we confirm the simple formulas experimentally. Crossfield may cause compass error up to 2.6 deg., depending on the compass orientation. The most effective way to suppress the crossfield error is using magnetic feedback, however this is not always possible. We suggest a method of processing of the SET/RESET sensor outputs which is more efficient than the usual averaging. </para>
8
Magnetic Sensors and Magnetometers
Pavel Ripka · Measurement Science and Technology · 2002 · 663 citations
Errors of AMR compass and methods of their compensation
Jan Včelák, Pavel Ripka, Antonı́n Platil et al. · Sensors and Actuators A Physical · 2005 · 65 citations
Michal Vopálenský, Pavel Ripka, Antonı́n Platil · Sensors and Actuators A Physical · 2003 · 64 citations
Magnetic Sensors and Magnetometers
John Rigelsford · Sensor Review · 2002 · 63 citations