Review on blackout process in China Southern area main power grid in 2008 snow disaster

Qingqian Chen, Xianggen Yin, Dahai You, Hui Hou, Bo Wang, Hui Liu

2009 · 46 citations · 2 references

Concepts

TL;DR

In early 2008, extreme cold, heavy rain, snow, and freezing temperatures severely disrupted southern China’s power grid, threatening its security and stability. The study proposes solutions and recommendations for power supply and grid development to address the identified issues. The authors review the full accident sequence of the 500 kV main power grid during the snow disaster, integrating grid characteristics and weather conditions. Key problems include a high proportion of long‑distance, high‑capacity lines, misalignment between power supply growth and grid expansion, and suboptimal 500 kV corridor selection.

Abstract

In the beginning of 2008, southern China had experienced extreme low temperature, heavy rain, snow, and freezing weather. This extreme weather had impaired the southern area power grid greatly and threatened the security and stability running of power system and power supply. The paper introduces the China southern area power grid basic disaster situation. Based on the China southern area power grid characters and the disastrous weather characters, it reviews the whole accident process of the 500 kV main power grid in the snow disaster. Then summarizes the typical characteristics in the disaster of China southern area 500 kV main power grid, and reveals the main problems exposed in the southern area 500 kV main power grid. The problems include: long distance large capacity transmission line proportion, the power supply development is not harmonious with the power grid development, and the 500 kV transmission line corridor selection problem, etc. Some solutions and recommendations in power supply development and power grid development are given out according to the problems in the end.

References

2