PLoS ONE · 2011 · 48 citations · 33 references
MedicineNuclear MedicinePharmacokineticsBiomedical ImagingDiagnostic ImagingNeuroradiologyBrain ImagingImage ReconstructionMedical ImagingHigh-resolution ImagingImage-derived Input FunctionPet Image ReconstructionPet KineticsPet QuantificationRadiotracer QuantificationResolution RecoveryTracer Studies
BACKGROUND: The aim of this study was to test seven previously published image-input methods in state-of-the-art high resolution PET brain images. Images were obtained with a High Resolution Research Tomograph plus a resolution-recovery reconstruction algorithm using two different radioligands with different radiometabolite fractions. Three of the methods required arterial blood samples to scale the image-input, and four were blood-free methods. METHODS: All seven methods were tested on twelve scans with [(11)C](R)-rolipram, which has a low radiometabolite fraction, and on nineteen scans with [(11)C]PBR28 (high radiometabolite fraction). Logan V(T) values for both blood and image inputs were calculated using the metabolite-corrected input functions. The agreement of image-derived Logan V(T) values with the reference blood-derived Logan V(T) values was quantified using a scoring system. Using the image input methods that gave the most accurate results with Logan analysis, we also performed kinetic modelling with a two-tissue compartment model. RESULTS: For both radioligands the highest scores were obtained with two blood-based methods, while the blood-free methods generally performed poorly. All methods gave higher scores with [(11)C](R)-rolipram, which has a lower metabolite fraction. Compartment modeling gave less reliable results, especially for the estimation of individual rate constants. CONCLUSION: OUR STUDY SHOWS THAT: 1) Image input methods that are validated for a specific tracer and a specific machine may not perform equally well in a different setting; 2) despite the use of high resolution PET images, blood samples are still necessary to obtain a reliable image input function; 3) the accuracy of image input may also vary between radioligands depending on the magnitude of the radiometabolite fraction: the higher the metabolite fraction of a given tracer (e.g., [(11)C]PBR28), the more difficult it is to obtain a reliable image-derived input function; and 4) in association with image inputs, graphical analyses should be preferred over compartmental modelling.
33
Learning the parts of objects by non-negative matrix factorization
Daniel D. Lee, H. Sebastian Seung · Nature · 1999 · 14.1K citations
Computerized three‐dimensional segmented human anatomy
I. George Zubal, Charles R. Harrell, E. O’Brian Smith et al. · Medical Physics · 1994 · 1.1K citations
Correction for partial volume effects in PET: principle and validation.
Olivier Rousset, Yilong Ma, Alan C. Evans · PubMed · 1998 · 934 citations
Kewei Chen, Daniel Bandy, Eric M. Reiman et al. · Journal of Cerebral Blood Flow & Metabolism · 1998 · 258 citations
Masahiro Fujita, Masao Imaizumi, Sami S. Zoghbi et al. · NeuroImage · 2007 · 213 citations · Full text