IEEE Transactions on Plasma Science · 1996 · 29 citations · 12 references
EngineeringElectrical EngineeringMechanical EngineeringElectric MachinesHeat TransferTransport PhenomenaDevice CharacterizationMagnetohydrodynamicsEnthalpyFaraday Disk GeneratorGenerator EfficiencyHall ConductivityHall EffectHall Effect MeasurementsPerformance CharacterizationTotal Pressure
The isentropic efficiency and the effective Hall parameter in a nonequilibrium disk MHD generator have been successfully evaluated on the basis of the experiments under high enthalpy extraction conditions. Special attention is devoted to measuring the exit total pressure and the Faraday current. The maximum isentropic efficiency achieved in the present experiments was 46% with the enthalpy extraction ratio of 31.6%. The experimentally obtained values of the effective Hall parameter covered a range of 2-3.
12
<i>Magnetohydrodynamic Energy Conversion</i>
R.J. Rosa, J. H. Kelley · Physics Today · 1969 · 338 citations
Pressure probes for fluid measurement
SH Chue · Progress in Aerospace Sciences · 1975 · 215 citations
MHD power generation with fully ionized seed
H. Yamasaki, S. Shioda · Journal of Energy · 1977 · 60 citations