Artificial Cells Blood Substitutes and Biotechnology · 2000 · 15 citations · 7 references
MedicineBiotechnologyNephrologyCell EngineeringDialysisHemodialysisAnimal Cell CultureCell Culture TechnologyCell EncapsulationMicrobial Cell EngineeringRenal ImpairmentRenal PharmacologyChronic Renal Insufficiency
High level of plasma creatinine occurs in renal insufficiency, uremia, and other diseases. At present lowering of this metabolite is done by using dialysis and other techniques. In this article, we report the use of artificial cells microencapsulated genetically engineered E. coli DH5 cells for lowering plasma creatinine in-vitro and in-vivo. Result shows that artificial cells were able to lower plasma creatinine in-vitro from 21.80 +/- 1.10 mg/dl to 21.80 +/- 1.10 mg/dl in 60 minutes and to 19.34 +/- 0.60 mg/dl in 3 hours. Result also shows that when given orally on a daily basis, artificial cells microencapsulated genetically engineered E. coli DH5 cells were also able to lower plasma creatinine in rats.
7