Applied Physics Letters · 2005 · 31 citations · 17 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsBiophotonicsOptical CoherenceOptical Coherence TomographyOptical ImagingOptical TomographyTendon ImagingTissue OpticsAxial ResolutionCollagen ImagingContrast EnhancementHarmonic GenerationOptical Characterization Of Biological TissueSecond-harmonic GenerationTissue Morphology AnalysisTissue Optical Diagnostics
A high-resolution second-harmonic optical coherence tomography (SH-OCT) system is demonstrated using a spectrum broadened femtosecond Ti:sapphire laser. An axial resolution of 4.2μm at the second-harmonic wave center wavelength of 400 nm has been achieved. Because the SH-OCT system uses the second-harmonic generation signals that strongly depend on the orientation, polarization, and local symmetry properties of chiral molecules, this technique provides unique contrast enhancement to conventional optical coherence tomography. The system is applied to image biological tissues of the rat-tail tendon. Highly organized collagen fibrils in the rat-tail tendon can be visualized in recorded images.
17
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
Warren R. Zipfel, Rebecca M. Williams, Richard H. Christie et al. · Proceedings of the National Academy of Sciences · 2003 · 1.7K citations · Full text
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Guillermo J. Tearney, Mark E. Brezinski, Brett E. Bouma et al. · Science · 1997 · 1.4K citations