IEEE Transactions on Power Electronics · 2007 · 130 citations · 19 references
EngineeringElectrical EngineeringEnergy SystemsPower ElectronicsRenewable Energy SystemsConverter TopologiesDc-dc ConversionPower Electronics For Renewable EnergyRenewable Energy Power ConversionSolar CellsSolar Photovoltaic SystemsBuck ConvertersBuck-boost ConvertersCurrent-fed ConvertersLeakage Inductance Energy RecoveryMagnetic Leakage InductanceMosfet Gate DriversPower Conversion For Photovoltaic SystemsSwitching Losses
In this paper, a photovoltaic (PV) module integrated converter is implemented with a current fed two-inductor boost converter cascaded with a line frequency unfolder. The current source is a sinusoidally modulated two-phase buck converter with an interphase transformer. The boost cell operates at a fixed duty ratio and has an integrated magnetic structure. The two inductors and the transformer are integrated into one magnetic core. Passive lossless snubbers are employed to recover the energy trapped in the transformer leakage inductance and to minimize the switching losses. The two-inductor boost converter output interfaces with the mains via an unfolding stage, where the MOSFETs are driven by the PV gate drivers. Experimental results are provided for a 100-W converter developing a single phase 240-V 50-Hz output
19
Inverters for single-phase grid connected photovoltaic systems-an overview
Martina Calais, Johanna Myrzik, Ted Spooner et al. · 2003 · 539 citations