Journal of Cataract & Refractive Surgery · 2014 · 22 citations · 12 references
MedicineOphthalmologyOptometryBinocular VisionClinical OptometryClinical Vision ScienceBinocular Vision AssessmentBinocular Vision EvaluationRefractive ErrorRefractive Error AssessmentVisual AcuityVisual ImpairmentMonofocal Intraocular LensesPseudophakic AstigmatismReading AcuityReading Performance MeasurementSight-reading Performance AssessmentSpherical Equivalent RefractionUncorrected Visual AcuityVisual Acuity Charts
PURPOSE: To evaluate reading performance of patients with monofocal intraocular lenses (IOLs) (Acrysof SN60WF) with or without reading glasses under bright and dim light conditions. SETTING: Austrian Academy of Ophthalmology, Vienna, Austria. DESIGN: Evaluation of a diagnostic test or technology. METHODS: In pseudophakic patients, the spherical refractive error was limited to between +0.50 diopter (D) and -0.75 D with astigmatism of 0.75 D (mean spherical equivalent: right eye, -0.08 ± 0.43 [SD]; left eye, -0.15 ± 0.35). Near addition was +2.75 D. Reading performance was assessed binocularly with or without reading glasses at an illumination of 100 candelas (cd)/m(2) and 4 cd/m(2) using the Radner Reading Charts. RESULTS: In the 25 patients evaluated, binocularly, the mean corrected distance visual acuity was -0.07 ± 0.06 logMAR and the mean uncorrected distance visual acuity was 0.01 ± 0.11 logMAR. The mean reading acuity with reading glasses was 0.02 ± 0.10 logRAD at 100 cd/m(2) and 0.12 ± 0.14 logRAD at 4 cd/m(2). Without reading glasses, it was 0.44 ± 0.13 logRAD and 0.56 ± 0.16 logRAD, respectively (P < .05). Without reading glasses and at 100 cd/m(2), 40% of patients read 0.4 logRAD at more than 80 words per minute (wpm), 68% exceeded this limit at 0.5 logRAD, and 92% exceeded it at 0.6 logRAD. The mean reading speed at 0.5 logRAD was 134.76 ± 48.22 wpm; with reading glasses it was 167.65 ± 32.77 wpm (P < .05). CONCLUSION: A considerable percentage of patients with monofocal IOLs read newspaper print size without glasses under good light conditions.
12
Eva Stifter, Franz König, Thomas Lang� et al. · Graefe s Archive for Clinical and Experimental Ophthalmology · 2003 · 135 citations
Education, Educational Assessment, Educational Measurement +13
Scott Greenbaum · Journal of Cataract & Refractive Surgery · 2002 · 110 citations
Medicine, Ophthalmology, Surgery +17
Reading ability with 3 multifocal intraocular lens models
Werner W. Hütz, Berthold H. Eckhardt, Bern Röhrig et al. · Journal of Cataract & Refractive Surgery · 2006 · 105 citations
Medicine, Ophthalmology, Surgery +17