Acta Orthopaedica Scandinavica · 1989 · 28 citations · 17 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopaedic BiomaterialsOrthopedicsJoint Replacement MaterialsJoint SurgeryKnee ArthroplastyLigament ReconstructionXenotransplantationComplications Of Xenograft UseCruciate Ligament SurgeryKnee Ligament ReconstructionLigament Graft Failure
In 28 patients the anterior cruciate ligament of the knee was substituted with a bovine bioprosthesis (Xenograft). Five patients underwent reoperations due to synovitis and graft rupture during the first postoperative year; and 2 patients, due to graft rupture after 3 years. After 3 years, 11/21 patients with a remaining graft had a rupture. Totally, 18/28 implanted grafts were considered to be ruptured. Our results indicate that the Xenograft in its present form should not be used.
17
Instrumented measurement of anterior laxity of the knee.
Dale M. Daniel, Lawrence Malcom, Gary M. Losse et al. · Journal of Bone and Joint Surgery · 1985 · 750 citations