Dose Rate Upset Investigations on the Xilinx Virtex IV Field Programmable Gate Arrays

Alonzo Vera, Daniel Llamocca, Marios S. Pattichis, W.T. Kemp, W. Shedd, David Alexander, James Lyke

2007 · 27 citations · 5 references

Concepts

Abstract

The following paper describes the results of ionizing dose rate investigations into upset, supply photocurrent, latch-up, and burnout susceptibility of the Xilinx Virtex IV XC4VFX12. All investigations were performed on a commercial version of the device. The maximum no-upset dose rate was 2.8times10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">8</sup> rad(Si)/s. Photocurrent amplitudes as a function of dose rate were recorded.

References

5