Journal of Physics Conference Series · 2008 · 31 citations · 1 references
Natural SciencesMaterials EngineeringMaterials ScienceDigital ImagingElectronic MaterialsOpticsAnalytical ImagingAtomic Force MicroscopyElectron Beam LithographyElectron MicroscopyGrain Structure AnalysisGrain-size AnalysisBackscattered Electron ImagingFocused Ion Beam LithographyFocused Ion Beam Scanning Electron MicroscopyScanning Electron MicroscopyScanning Electron Microscopy Analysis
Grain contrast imaging can be performed with several techniques. In order to be able to choose the most suitable one it is important to know which techniques are available and also to be aware of the strengths and weaknesses of each technique. In this work, the grain contrast imaging is performed with secondary electrons, backscattered electrons, forward scattered electrons, transmitted electrons in the scanning electron microscope, and with secondary electrons in the focused ion beam instrument. The advantages and disadvantages of each method are discussed in order to make it easier to choose the most appropriate technique for grain contrast imaging.
1