IEEE Transactions on Electromagnetic Compatibility · 2008 · 35 citations · 12 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesMagnetic Circuit AnalysisPermanent Magnet MachinesSynchronous MachinesCapacitorsCommon-mode InterferenceHigh-frequency InvertersHigh-frequency ModelingInverter ModelingPermanent Magnet MotorsPermanent Magnet Synchronous MotorsSynchronous Machine Modeling
In this paper, a model for permanent magnet synchronous motors to deal with high-frequency emissions from an inverter system is proposed and analyzed. The model permits study of the common-mode (CM) effects on the motor line currents. The experimental measurements show that the CM stray capacitors are not affected by rotor magnet positions. The simulated and experimental results show that the CM currents increase with decreasing sampling time.
12