Applied and Environmental Microbiology · 1989 · 84 citations · 10 references
Life SciencesInfectious DiseasesMicrobiologyMedical MicrobiologyVirologyWater TreatmentBacterial SporesEnvironmental DisinfectionHigh-level DisinfectionPathogen ControlBacillus SporesBacillus SubtilisEscherichia ColiOzoneOzone SanitizationPathogen Indicator OrganismsTemperature Effects On DisinfectionWater Disinfection Systems
In steadily flowing water at 20 degrees C and pH 7, five organisms had the following order of resistance to ozone (at constant levels of ozone): poliovirus 1 (PV1) less than Escherichia coli less than hepatitis A virus (HAV) less than Legionella pneumophila serogroup 6 less than Bacillus subtilis spores. The tests were repeated at 10 degrees C with HAV, PV1, and E. coli. Ozone inactivation of HAV and E. coli was faster at 10 degrees C than at 20 degrees C. At 20 degrees C, 0.25 to 0.38 mg of O3 per liter was required for complete inactivation of HAV but only 0.13 mg of O3 per liter was required for complete inactivation of PV1.
10
Detection of enteric viruses in treated drinking water
Bruce H. Keswick, Charles P. Gerba, Herbert L. DuPont et al. · Applied and Environmental Microbiology · 1984 · 122 citations · Full text
Pierre Payment, M. Trudel, Robert Plante · Applied and Environmental Microbiology · 1985 · 113 citations · Full text