IEEE Transactions on Plasma Science · 1996 · 39 citations · 8 references
EngineeringElectrical EngineeringPhysicsPlasma PhysicsRadiation TransportSemiconductor DevicesImplant MaterialsImplant TechnologyIntegrated Circuit DesignIon ImplantationPlasma SheathsEnergy Coupling EfficiencyGate Oxide DegradationGate Oxide InterfacesHigh Current Ion ImplantationIon Energy Distribution In SheathsPlasma Immersion Ion ImplantationSheath CharacteristicsVoltage
Plasma immersion ion implantation (PIII) is a novel implantation technique for high-dose/high-current implants. Using the SPICE circuit simulator to model the PIII process, the sheath voltage and ion energy distribution are examined. Implanting into a dielectric substrate results in a significant voltage buildup in the wafer, reducing the effective implant energy. Increasing the pulse voltage raises the dose/pulse, but at the cost of an expanded implant energy spread. Increasing the plasma ion density also raises the dose/pulse, but at the cost of a wider implant energy spread and a lower coupling efficiency. Increasing the substrate thickness reduces both the coupling efficiency and dose/pulse while broadening the energy spread. The large voltage generated across the dielectric substrate decreases the charge neutralization time significantly, reducing the possibility of gate oxide damage.
8
Model of plasma immersion ion implantation
M. A. Lieberman · Journal of Applied Physics · 1989 · 292 citations