European Journal of Nuclear Medicine and Molecular Imaging · 2011 · 119 citations · 38 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyImage ReconstructionMedical ImagingOncologic Hybrid ImagingPositron Emission TomographyTumor CharacterizationTumor ImagingGatingLung Tumor ImagingNoise CharacteristicsOncologic Pet ImagingPet Image ReconstructionPet QuantificationReconstruction AlgorithmsTumor Volumetry
PURPOSE: We investigated the added value of a new respiratory amplitude-based PET reconstruction method called optimal gating (OG) with the aim of providing accurate image quantification in lung cancer. METHODS: FDG-PET imaging was performed in 26 lung cancer patients during free breathing using a 24-min list-mode acquisition on a PET/CT scanner. The data were reconstructed using three methods: standard 3D PET, respiratory-correlated 4D PET using a phase-binning algorithm, and OG. These datasets were compared in terms of the maximum SUV (SUVmax) in the primary tumour (main endpoint), noise characteristics, and volumes using thresholded regions of SUV 2.5 and 40% of the SUVmax. RESULTS: SUVmax values from the 4D method (13.7 ± 5.6) and the OG method (14.1 ± 6.5) were higher (4.9 ± 4.8%, p < 0.001 and 6.9 ± 8.8%, p < 0.001, respectively) than that from the 3D method (13.1 ± 5.4). SUVmax did not differ between the 4D and OG methods (2.0 ± 8.4%, p = NS). Absolute and relative threshold volumes did not differ between methods, except for the 40% SUVmax volume in which the value from the 3D method was lower than that from the 4D method (-5.3 ± 7.1%, p = 0.007). The OG method exhibited less noise than the 4D method. Variations in volumes and SUVmax of up to 40% and 27%, respectively, of the individual gates of the 4D method were also observed. CONCLUSION: The maximum SUVs from the OG and 4D methods were comparable and significantly higher than that from the 3D method, yet the OG method was visibly less noisy than the 4D method. Based on the better quantification of the maximum and the less noisy appearance, we conclude that OG PET is a better alternative to both 3D PET, which suffers from breathing averaging, and the noisy images of a 4D PET.
38
The Fourier transform and its applications
M. L. J. Hautus · European Journal of Operational Research · 1980 · 1.1K citations
Ursula Nestle, Stephanie Kremp, Andrea Schaefer-Schuler et al. · PubMed · 2005 · 615 citations
Medicine, Nuclear Medicine, Oncology +17
Effect of respiratory gating on quantifying PET images of lung cancer.
Sadek A. Nehmeh, Yusuf E. Erdi, Clifton C. Ling et al. · PubMed · 2002 · 410 citations
Ronald Boellaard, Wim J.G. Oyen, C. Hoekstra et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2008 · 393 citations · Full text