Applied Spectroscopy · 2003 · 148 citations · 62 references
Natural SciencesChemistryInstrumentationPhotonicsSpectroscopyInfrared InstrumentationInfrared SpectroscopyNear-infrared SpectroscopyOptical SpectroscopyTime-resolved SpectroscopyUltraviolet-visible SpectroscopyData Acquisition ElectronicsNear-infrared InstrumentationPicosecond SpectroscopyResonance Raman SpectroscopyTime-resolved Infrared SpectroscopyTime-resolved Raman SpectroscopyTransient Absorption SpectroscopyUltrafast Spectroscopy
The authors present preliminary picosecond TRIR studies using the new spectrometer and show that combining TRIR with TR3 spectroscopy yields key information for fully elucidating a photochemical process. The TRIR spectrometer employs broadband 150‑fs mid‑IR probe and reference pulses generated by difference‑frequency mixing in AgGaS₂, dispersed onto two 64‑element HgCdTe arrays, and coupled to custom electronics that perform shot‑by‑shot signal handling at 1 kHz for real‑time data processing. The integrated instrument achieves ΔOD sensitivity of 10⁻⁴–10⁻⁵ in one minute, enabling preliminary picosecond TRIR studies that, when combined with TR3, provide key insights into photochemical processes.
We have constructed a broadband ultrafast time-resolved infrared (TRIR) spectrometer and incorporated it into our existing time-resolved spectroscopy apparatus, thus creating a single instrument capable of performing the complementary techniques of femto-/picosecond time-resolved resonance Raman (TR 3 ), fluorescence, and UV/visible/infrared transient absorption spectroscopy. The TRIR spectrometer employs broadband (150 fs, ∼150 cm −1 FWHM) mid-infrared probe and reference pulses (generated by difference frequency mixing of near-infrared pulses in type I AgGaS 2 ), which are dispersed over two 64-element linear infrared array detectors (HgCdTe). These are coupled via custom-built data acquisition electronics to a personal computer for data processing. This data acquisition system performs signal handling on a shot-by-shot basis at the 1 kHz repetition rate of the pulsed laser system. The combination of real-time signal processing and the ability to normalize each probe and reference pulse has enabled us to achieve a high sensitivity on the order of ΔOD ∼ 10 −4 –10 −5 with 1 min of acquisition time. We present preliminary picosecond TRIR studies using this spectrometer and also demonstrate how a combination of TRIR and TR 3 spectroscopy can provide key information for the full elucidation of a photochemical process.
62
A molecular light switch for DNA: Ru(bpy)2(dppz)2+
Alan E. Friedman, J.‐C. Chambron, Jean Pierre Sauvage et al. · Journal of the American Chemical Society · 1990 · 1.4K citations
Charge transfer and transport in DNA
Joshua Jortner, M. Bixon, Thomas Langenbacher et al. · Proceedings of the National Academy of Sciences · 1998 · 727 citations