PLoS ONE · 2012 · 16 citations · 31 references
Veterinary MedicineImmunologyInfectious DiseasesDiagnostic MicrobiologyMolecular DiagnosticsVirologyAntigen Detection AssaysDiagnostic ImmunologyDiagnosticsInfectious Disease DetectionInfectious Disease Molecular TestingViral DiagnosticsFlu-like SyndromeInfluenza DiagnosticsPoint-of-care Microbiology TestingPoint-of-care Viral TestingPolymerase Chain Reaction SensitivitySensitivityViral Antigen DetectionViral Serology Screening
BACKGROUND: For the diagnosis of seasonal influenza, clinicians rely on point-of-care testing (POCT) using commercially available kits developed against seasonal influenza viruses. However, POCT has not yet been established for the diagnosis of pandemic influenza A virus (H1N1pdm) infection due to the low sensitivity of the existing kits for H1N1pdm. METHODOLOGY/PRINCIPAL FINDINGS: An immunochromatography (IC) test kit was developed based on a monoclonal antibody against H1N1pdm, which does not cross-react with seasonal influenza A or B viruses. The efficacy of this kit (PDM-IC kit) for the diagnosis of H1N1pdm infection was compared with that of an existing kit for the detection of seasonal influenza viruses (SEA-IC kit). Nasal swabs (n = 542) were obtained from patients with flu-like syndrome at 13 clinics in Osaka, Japan during the winter of 2010/2011. Among the 542 samples, randomly selected 332 were further evaluated for viral presence by reverse transcriptase polymerase chain reaction (RT-PCR). The PDM-IC kit versus the SEA-IC kit showed higher sensitivity to and specificity for H1N1pdm, despite several inconsistencies between the two kits or between the kits and RT-PCR. Consequently, greater numbers of false-negative and false-positive cases were documented when the SEA-IC kit was employed. Significant correlation coefficients for sensitivity, specificity, and negative prediction values between the two kits were observed at individual clinics, indicating that the results could be affected by clinic-related techniques for sampling and kit handling. Importantly, many patients (especially influenza-negative cases) were prescribed anti-influenza drugs that were incongruous with their condition, largely due to physician preference for patient responses to questionnaires and patient symptomology, as opposed to actual viral presence. CONCLUSIONS/SIGNIFICANCE: Concomitant use of SEA-IC and PDM-IC kits increased the likelihood of correct influenza diagnosis. Increasing the credibility of POCT is anticipated to decrease the inappropriate dispensing of anti-influenza drugs, thereby minimizing the emergence of drug-resistant H1N1pdm strains.
31
Pandemic Potential of a Strain of Influenza A (H1N1): Early Findings
Christophe Fraser, Christl A. Donnelly, Simon Cauchemez et al. · Science · 2009 · 2K citations · Full text
In vitro and in vivo characterization of new swine-origin H1N1 influenza viruses
Yasushi Itoh, Kyoko Shinya, Maki Kiso et al. · Nature · 2009 · 1.1K citations · Full text
Resistant influenza A viruses in children treated with oseltamivir: descriptive study
Maki Kiso, Keiko Mitamura, Yuko Sakai‐Tagawa et al. · The Lancet · 2004 · 795 citations
Epidemiology of fatal cases associated with pandemic H1N1 influenza 2009
L Vaillant, Guy La Ruche, Arnaud Tarantola et al. · Eurosurveillance · 2009 · 350 citations · Full text
Veterinary Medicine, Geriatric Medicine, Infectious Diseases +12