Publication | Closed Access
Phase-conjugate holographic system for high-resolution particle-image velocimetry
233
Citations
14
References
1994
Year
HolographyEngineeringMicroscopyFluid MechanicsHolographic MethodPhase-conjugate Holographic SystemDigital HolographyRecording SystemDigital Image CorrelationImaging SystemRadiologyHealth SciencesPhysicsMedical ImagingReference MultiplexedBiomedical ImagingApplied PhysicsFlow Measurement3D Imaging
A novel holographic particle-image velocimeter system has been developed for the study of threedimensional (3-D) fluid velocity fields. The recording system produces 3-D particle images with a resolution, a signal-to-noise ratio, an accuracy, and derived velocity fields that are comparable to high-quality two-dimensional photographic particle-image velocimetry (PIV). The high image resolution is accomplished through the use of low f-number optics, a fringe-stabilized processing chemistry, and a phase conjugate play-back geometry that compensates for aberrations in the imaging system. In addition, the system employs a reference multiplexed, off-axis geometry for the determination of velocity directions with the cross-correlation technique, and a stereo camera geometry for the determination of the three velocity components. The combination of the imaging and reconstruction subsystems makes the analysis of volumetric PIV domains feasible.
| Year | Citations | |
|---|---|---|
Page 1
Page 1