EngineeringMaterials EngineeringMaterials ScienceElectronic MaterialsRadiation DetectionSemiconductor MaterialsDefects In Electronic MaterialsMetal-semiconductor ContactsPhotodetectorsSemiconductor DefectsSemiconductor DetectorsSemiconductor InterfacesDeposition DefectsDetector FabricationDetectorsElectroless DepositionGamma-ray Detector ResponseMetal-metal ContactsMetal-semiconductor InterfacesSurface Defects Characterization
Abstract The influence of deposition methods and type of metal contacts on the defects generated at the metal/semiconductor interface has been investigated. Photoluminesccence spectra at a low temperature demonstrated that the Au electroless deposition samples exhibit the lowest I (D 0 ,X) / I A-center ratio and have the best gamma response. Rutherford backscattering spectrometry results show that the sputtering method creates the highest concentration of TeO 2 layer compared with the evaporation and electroless deposition methods. The electroless Au has more inter-diffusion between the contact and the CZT material than either sputtering or evaporation methods. The electroless Pt and Ru depositions, however, exhibit lower inter-diffusion. The contacts deposited by electroless and evaporation present more quasi-ohmic behaviour and better gamma response than those fabricated by sputtering.
14
Influence of surface preparation on CdZnTe nuclear radiation detectors
Q. Zheng, F. Dierre, J. Crocco et al. · Applied Surface Science · 2011 · 49 citations
E. Y. Lee, R. B. James, R. W. Olsen et al. · Journal of Electronic Materials · 1999 · 48 citations