H atom detection and energy analysis by use of thin foils and TOF technique

M. Gruntman, V. A. Morozov

Journal of Physics E Scientific Instruments · 1982 · 30 citations · 2 references

Concepts

Abstract

It has been shown experimentally that detection and energy analysis of H atoms with energy 600-3000 eV can be performed successfully by means of a time-of-flight technique using secondary electron emission detectors and thin foils. The registration of particle fluxes in the presence of a superior ultraviolet background is possible. This technique may be applied to diagnostics of high-temperature and space plasmas.

References

2