IEEE Transactions on Industrial Electronics · 2011 · 774 citations · 30 references
EngineeringElectrical EngineeringCircuit TheoryPower ElectronicsVulnerability AnalysisDc-dc ConvertersElectrical System DiagnosticsFault DetectionFault DiagnosisPower Grid AnalysisProtection SystemsFault AnalysisFault LocationFault ProtectionGround Fault IdentificationPower ConvertersPower System Fault AnalysisPower System OperationShort-circuit Analysis
High‑power voltage‑source converters in multiterminal DC networks are attractive but lack operational experience, protective devices, and fault‑analysis techniques, making them vulnerable to short‑circuit and ground faults in interconnecting cables that threaten system operation. This study analyzes cable faults in VSC‑based DC networks, identifies critical fault stages to avoid, and proposes a fault‑location method as a prerequisite for effective protection. The authors locate short‑circuit faults by comparing voltage references and estimate ground‑fault distance and resistance by analyzing the initial transient of the fault. Simulation results show that short‑circuit fault distance can be evaluated easily, and the proposed ground‑fault location method performs accurately across a range of resistances, distances, and operating conditions.
The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.
30