Review of Scientific Instruments · 2006 · 11 citations · 3 references
Natural SciencesPhysicsInstrumentationNuclear InstrumentationPlasma PhysicsCharged Particle DetectionPlasma DiagnosticsPlasma FundamentalsCharge Exchange EffectsCharge Exchange ProcessesCharge-exchange ReactionsCharge-sensitive AmplifiersDetector Array SystemsNeutral Particle AnalysisPlasma Heating SystemsPulse Height Analysis
A new multichannel diagnostic for fast ion distribution studies has been developed and successfully tested on the Large Helical Device (LHD) in different plasma heating conditions. The diagnostic is based on a linear array AXUV detector consisting of 20 segments, charge sensitive preamplifiers, and a set of pulse height analysis channels. The main advantage of this system is the possibility to make time, energy, and angle-resolved measurements of charge exchange neutral particles in a single plasma discharge. This feature makes the new diagnostic a very helpful and powerful tool intended to contribute to the understanding of fast ion behavior in a complex helical plasma geometry like the one of LHD.
3
Magnetic field structure and confinement of energetic particles in the LHD
T. Watanabe, Yutaka Matsumoto, M Hishiki et al. · Nuclear Fusion · 2006 · 43 citations