IEEE Transactions on Electrical Insulation · 1984 · 22 citations · 18 references
Natural SciencesElectrical EngineeringMaterials ScienceElectrochemistryInterface ScienceSurface ScienceCurrent DistributionDevice SimulationElectrical ConductivityElectrode MaterialsInsulation SystemsSurface ChargeElectric Field DistributionElectrode DesignElectrode GeometryElectrode Geometry EffectsElectrode Geometry OptimizationElectrode InterfacesFlashoverFlashover Modeling
The electric field distribution along the interface of a solid insulator-vacuum (or gas) is analyzed for different solid insulator-electrode configurations with and without the presence of surface charges using the charge simulation technique. The tangential component of the electric field at the solid insulator-electrodevacuum (or gas) triple junction is found to be reduced in cases where the contact electrode extends into the solid insulator and where the solid insulator is placed in a recessed electrode. The reduction in the field increases with increasing the penetration length of the metal insert and the depth of the recess in the electrode. The results give a theoretical justification for the previously observed higher flashover values for insulators with metal inserts and for those placed in recessed electrodes.
18