Catheterization and Cardiovascular Interventions · 1999 · 46 citations · 10 references
MedicineBioengineeringCardiologyDrug DeliveryInterventional CardiologySurgical InstrumentationBiomedical InstrumentationCardiac CatheterizationCatheter GuidanceCoronary PerforationDirect Tissue Injection
Direct myocardial injection of therapeutic agents has been explored as a new method for myocardial revascularization. The integration of a 3D electromechanical mapping catheter with a retractable injection needle should allow for intramyocardial injection to identified sites, obviating the need for open heart surgery. This study assessed the procedural safety and performance characteristics of a novel guided catheter-based transendocardial injection system. The electromagnetic guidance system was coupled with a retrievable 27G needle for left ventricular endocardial injection. Using this system, we injected, transendocardially, methylene-blue (MB) dye tracer at a volume of 0.1 or 0.2 ml per injection in eight normal pigs. Animals were sacrificed acutely, at 1, 3, and 7 days (two animal in each time). Three animals served as controls. The injections were followed by coronary angiography and echocardiogram to assess possible ventricular or coronary perforation and wall motion abnormalities. CK-MB levels were measured up to 24 hr following the procedure. The animals were sacrificed at the assigned time for gross and histopathology evaluation. A total of 101 injections were made in all regions of the heart except the apex and the mitral valve. No animal died as a result of the mapping or injection procedures. Vital signs did not change relative to baseline after the mapping and injection procedures. CK-MB values did not increase over time and there was no evidence of sustained arrhythmia or hemodynamic compromise. There was no evidence of left ventricular or coronary perforation, global or regional wall motion abnormalities, or hemopericardium. On histologic evaluation, the estimated volume of tissue staining was greater than the volume of the injected MB dye due to dispersion of the injectate in the interstitial and intracellular fluid compartments. It is concluded that using this magnetic guidance catheter-based navigational system, it is feasible and safe to perform the transendocardial injection procedure. Thus, if it is determined that direct intramyocardial injection of drugs is a valid therapeutic strategy, this approach offers a clear advantage over surgically based transepicardial injection procedures. Cathet. Cardiovasc. Intervent. 48:447-453, 1999.
10
Gene Therapy for Myocardial Angiogenesis
Douglas W. Losordo, Peter R. Vale, James F. Symes et al. · Circulation · 1998 · 993 citations · Full text
Medicine, Biotechnology, Cardiology +12
Induction of Neoangiogenesis in Ischemic Myocardium by Human Growth Factors
Björn Schumacher, P Pecher, B. U. Specht et al. · Circulation · 1998 · 531 citations
Medicine, Cardiology, Pathobiology +17
Nonfluoroscopic, in vivo navigation and mapping technology
Shlomo A. Ben‐Haim, Daniel Osadchy, Israel Scnuster et al. · Nature Medicine · 1996 · 374 citations