Journal of Agricultural and Food Chemistry · 2001 · 27 citations · 15 references
PharmacyPharmaceutical AnalysisAnalytical ChemistryAnalytical ToxicologyFood MicrobiologyBioanalytical Method ValidationContaminant AnalysisAnalytical Methods DevelopmentBiological Sample AnalysisCapillary ElectrophoresisCapillary Zone ElectrophoresisDetection Limit AnalysisInstrument Detection LimitMethod Detection LimitZone Electrophoresis
A method of capillary zone electrophoresis (CZE) was used to determine tetracycline and streptomycin content in commercial agriculture products. The results indicated that this method was capable of analyzing the mixed fungicide in formulated products with instrument detection limit (IDL) of 0.50 microg/mL and a method detection limit (MDL) of 0.52 microg/mL for tetracycline, and IDL of 1.00 microg/mL and MDL of 1.22 microg/mL for streptomycin. Precision expressed by relative standard deviation (RSD) ranged from 1.44 to 4.37% of tetracycline and 1.00 to 4.20% of streptomycin. Recoveries were in the region of 98.2-102.5% for tetracycline and 95.3--103.0% for streptomycin. The low detection limit, the low RSD values, and the high percentage of recovery confirmed that the CZE technique is a sensitive and selective method. And the CZE method can analyze both tetracycline and streptomycin at the same time without complicated extraction and further derivative reaction.
15
James H. Boothe, J. Morton, J. P. Petisi et al. · Journal of the American Chemical Society · 1953 · 72 citations