Optics Letters · 2003 · 10 citations · 0 references
Natural SciencesPhysicsBiomedical OpticsOpticsOptoelectronicsFourier OpticsInterferometryOptical AberrationsOptical InstrumentationOptical MetrologyPhysical OpticsAberration CorrectionsAberration MeasurementExperimental Results InterpretationInterferometric MeasurementLiquid Crystal DisplaysOptical InterferometersPhase Shifting Interferometry
We propose a new method for evaluating and correcting aberrations in a Vander Lugt correlator. The technique is achieved with liquid-crystal displays of the correlator and allows the task to be performed in situ. We present the theory on which the method is based and the experimental results that we obtained by applying it in a convergent correlator.