Optics Letters · 2014 · 46 citations · 18 references
Natural SciencesChemistryPhysicsAnalytical ChemistryChemical KineticsSpectroscopyFluorescence SpectroscopyLaser SpectroscopyOptical SpectroscopyExcitationLaser-induced FluorescencePlanar Laser-induced FluorescenceQuantum ThermalizationRotational TemperatureSpontaneous EmissionThermalizationVibrationally Excited State Spectroscopy
We present measurements demonstrating simultaneous determination of velocity and temperature using a variant of the Vibrationally Excited Nitric Oxide Monitoring (VENOM) technique that does not employ NO2. The variant is based on tagging by electronic excitation of NO in the A²∑(1/2)⁺ (v'=0)←X2Π1/2(v''=0) band and subsequent formation of vibrationally excited NO(X2Π) by spontaneous emission and collisional quenching. Sequential planar laser-induced fluorescence imaging of the nascent NO(X2Π, v''=1) was used to obtain spatially resolved average streamwise velocity and rotational/translational temperature. The temperature determination using this approach extends the applicability of the VENOM technique to low-density, high-speed flows, where slow thermalization of the tagged molecules represents a limiting factor.
18
Flow-Tagging Velocimetry for Hypersonic Flows Using Fluorescence of Nitric Oxide
Paul M. Danehy, Sean O’Byrne, A. Frank et al. · AIAA Journal · 2003 · 169 citations · Full text
Molecular Tagging Using Vibrationally Excited Nitric Oxide in an Underexpanded Jet Flowfield
Andrea Hsu, Ravi Srinivasan, Rodney Bowersox et al. · AIAA Journal · 2009 · 78 citations
Natural Sciences, Chemistry, Physics +15