Detection of colonic inflammation with Fourier transform infrared spectroscopy using a flexible silver halide fiber

Vinay Katukuri, John Hargrove, Sharon Miller, Kinan Rahal, John Y. Kao, Rolf Wolters, Ellen M. Zimmermann, Thomas D. Wang

Biomedical Optics Express · 2010 · 15 citations · 28 references

DOIFull text

Open access

Concepts

Abstract

Persistent colonic inflammation increases risk for cancer, but mucosal appearance on conventional endoscopy correlates poorly with histology. Here we demonstrate the use of a flexible silver halide fiber to collect mid-infrared absorption spectra and an interval model to distinguish colitis from normal mucosa in dextran sulfate sodium treated mice. The spectral regime between 950 and 1800 cm(-1) was collected from excised colonic specimens and compared with histology. Our model identified 3 sub-ranges that optimize the classification results, and the performance for detecting inflammation resulted in a sensitivity, specificity, accuracy, and positive predictive value of 92%, 88%, 90%, and 88%, respectively.

References

28