PubMed · 2014 · 12 citations · 46 references
AgricultureFood ScienceMicrobiologyDiagnostic MicrobiologyFood MicrobiologyFood SafetyBacterial IdentificationFood BacteriologyFoodborne Pathogen DetectionMicrobial Food SafetyPathogen DetectionPathogen Detection In FoodsBacterial DetectionMelting Curve AnalysisMolecular Detection Of BacteriaPcr-based DetectionPolymerase Chain Reaction (Pcr) AssaysPolymerase Chain Reaction (Pcr)-based IdentificationRapid Microbial Diagnostics
OBJECTIVE: This study is aimed to develop a two-tube melting curve-based multiplex real time PCR assay (MCMRT-PCR) for the simultaneous detection of six common foodborne pathogenic bacteria (diarrhoeagenic Escherichia coli, Salmonella, and Shigella in tube 1, Staphylococcus aureus, Vibrio parahaemolyticus, and Listeria monocytogenes in tube 2). METHODS: A two-tube MCMRT-PCR assay was performed on 7900HT Fast Real-Time PCR System (Applied Biosystems, USA). Amplification by PCR was optimized to obtain high efficiency. The sensitivity and specificity of assays were investigated. RESULTS: The detection limit of optimized MCMRT-PCR assay was 3.9×102 CFU/mL for S. aureus, 4.4×102 CFU/mL for L. monocytogenes, 3.0×102 CFU/mL for Salmonella, 2.5×102 CFU/mL for Shigella, 2.1×102 CFU/mL for V. parahaemolyticus, and 1.2×102 CFU/mL for E. coli. The feasibility of MCMRT-PCR was further evaluated using artificially contaminated milk, the sensitivity was at the level of 105 CFU/mL. CONCLUSION: A two-tube MCMRT-PCR assay using six primer sets was developed for detection of multiple pathogens. Our findings demonstrates that the proposed two-tube assay is reliable, useful and rapid for simultaneous detection of six foodborne pathogenic bacteria with an intended application in provincial Centers for Diseases Control and Prevention (CDC).
46
Jessica L. Nordstrom, Michael C.L. Vickery, George M. Blackstone et al. · Applied and Environmental Microbiology · 2007 · 353 citations · Full text