Comparison of resistive and capacitive strain gauge sensors printed on polyimide substrate using ink-jet printing technology

Čedo Žlebič, Nikola Ivanisevic, Milica Kisić, Nelu Blaž, Aleksandar Menicanin, Lj. Živanov, Mirjana Damnjanović

2014 · 12 citations · 5 references

Concepts

Abstract

In this paper we compared a resistive and capacitive strain gauge in terms of sensitivity and material cost, both printed with deposition material printer using silver nanoparticle ink on a flexible polyimide substrate. The resistive change due to strain was measured with a full Wheatstone bridge and a signal conditioning circuit, while the capacitance change was measured with the HP4194A impedance analyzer. Measured and derived strain gauge factor for resistive sensor was 1.10, and 0.91 for the capacitive sensor.

References

5