Study on the reliability of the mechanical shutter utilizing roll actuators

Che-Heung Kim, Seogwoo Hong

2011 · 11 citations · 2 references

Concepts

Abstract

This paper handles a single approach to solve two major reliability issues of the previously proposed micro shutter using roll actuators. Material and structural change from Al/SiN <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</sub> to Mo/Mo improves the temperature stability of an aperture size by matching CTEs of bi-layer ideally. It is also effective to extend the rated lifetime of the shutter by eliminating a dielectric charging layer, SiNx. The measured temperature-invariant diameter of the Mo/Mo roll from 25°C to 80°C is compared with a dramatic change of the former Al/SiNx roll, which proves our approach effective. The rated lifetime reaches 200,000 (5 times higher than the previous work) just after applying Mo/Mo roll and 350,000 (1.7 times more) when dimples are added on it.

References

2