Medical Principles and Practice · 2010 · 59 citations · 19 references
DentistryMicrobiologyOral BiologyMicrobial EcologyMicrobial PhysiologyOral MicrobiologyAnaerobic BacteriologyMicrobiological AnalysisMicrobiological QualityMicrobiological SamplingOral Microbial MetabolismEnrichment BrothFacultative Anaerobic BacteriaMicrobial Volatile Organic CompoundsOral Bacterial MetabolismOral Microbial AssessmentPlaque Microbial CompositionSulfur Volatile CompoundsVolatile Sulfur Compounds
<i>Objective:</i> To compare the use of the Halimeter and the Oral Chroma™ to assess the ability of common oral anaerobic bacteria isolated from the Kuwaiti population to produce volatile sulfur compounds (VSCs). <i>Materials and Methods:</i> Broth cultures of common anaerobes isolated from supragingival plaque were centrifuged and pellets resuspended in phosphate buffer (pH 7.7) with an optical density OD<sub>550</sub> of 0.3. 100 µl of this suspension and 870 µl of buffer were added in 2 sterile 15-ml head space vials. Reaction was initiated by addition of 30 µl of 33 m<i>M</i><i>L</i>-methionine and <i>L</i>-cysteine, respectively, in each vial and incubation at 37°C for 90 min. 500 µl of 3 <i>M</i> phosphoric acid was added to tubes and was kept aside for 10 min. Production of VSCs was measured using the Halimeter and the Oral Chroma. <i>Results:</i> The major VSC producers identified by both Halimeter and Oral Chroma with <i>L</i>-cystenine as substrate were <i>Campylobacter ureolyticus</i>, <i>Porphyromonas gingivalis</i>, <i>Tannerella forsythia</i>, <i>Prevotella intermedia</i>, <i>Aggregatibacter actinomycetemcomitans</i> and <i>Gemella morbillorum</i>. The concentrations of hydrogen sulfide recorded by both Halimeter and Oral Chroma were essentially identical. With <i>L</i>-methionine as substrate, both Halimeter and Oral Chroma identified different complements of anaerobes with C<i>. ureolyticus,</i><i>P. gingivalis,</i><i>Fusobacterium nucleatum </i>and <i>P. intermedia</i> as major VSC producers. The concentrations of methyl mercaptan recorded by the Halimeter were lower compared to those assessed by the Oral Chroma. <i>Conclusion:</i> The results suggest that the Oral Chroma may produce a more comprehensive assessment of VSC production by oral microflora than the Halimeter.
19
The formation of hydrogen sulfide and methyl mercaptan by oral bacteria
Sten Persson, M. Edlund, Rolf Claesson et al. · Oral Microbiology and Immunology · 1990 · 517 citations
Cadaverine as a Putative Component of Oral Malodor
Sarah Goldberg, Avital Kozlovsky, Dalia Gordon et al. · Journal of Dental Research · 1994 · 206 citations