2012 · 11 citations · 4 references
EngineeringElectrical EngineeringMicroelectronicsPower ElectronicsSemiconductor DevicesDevice CharacterizationElectrical System DiagnosticsElectronics TechnologyPower SystemsEnergy Loss AnalysisEnergy Loss DetectionJunction ResistancePower ConvertersPower Electronic ConvertersPower Loss ModelingSwitching LossesSwitching-induced Losses
Device switching times and switching energy losses are required over a wide range of practical working conditions for successful design of insulated gate bipolar transistor (IGBT) based power converters. This paper presents a cost-effective experimental setup using a co-axial current transformer for measurement of IGBT switching characteristics and switching energy loss. Measurements are carried out on a 50A, 1200V IGBT (SKM50GB123D) for different values of gate resistance, device current and junction temperature. These measurements augment the technical data available in the device datasheet.Short circuit transients are also investigated experimentally under hard switched fault as well as fault under load conditions.
4
R.O.C. Lyra, Braz J. Cardoso Filho, Vinod John et al. · IEEE Transactions on Industry Applications · 2000 · 24 citations · Full text