Particle sizes of colloids to be used in sentinel lymph node radiolocalization
69
Citations
14
References
2008
Year
The particle sizes of Nanocoll, Nanocis and Hepatate are very stable throughout their period of validity. For Nanocoll, 95% of particles have a diameter <16 nm, with a mean diameter around 8 nm. There are small (< or =1 nm) but significant variations on the mean diameter depending on the volume of pertechnetate used in its preparation. For Nanocis, 95% of particles have a diameter <70 nm, with a mean around 24 nm, and are independent of the volume of pertechnetate used in their preparation. For Hepatate, the upper size limit for 95% of particles is between 190 and 255 nm, with a mean between 72 and 88 nm, depending on the volume of pertechnetate used in its preparation. This tin colloid could be a good candidate for evaluating clinical suitability in sentinel node localization.