EngineeringElectrical EngineeringAnalog ElectronicsMicrowave EngineeringSpectroscopyAtomic ClocksMicrowave OscillatorsMicrowave ResonatorsNoiseNoise MeasurementOscillatorsAbsolute FrequencyAbsolute StabilityAllan VarianceFrequency StabilityPhase NoisePhase Noise AnalysisResonator Frequency StabilityStabilization
Oscillators based on cryogenic sapphire resonators can supply the levels of microwave phase noise and frequency stability required for advanced time-and-frequency applications. NPL has realized two such oscillators of identical design, which operate at 9.204 GHz and incorporate both Pound-loop and power stabilization. Running both simultaneously, and comparing their outputs both to each other and to H-maser-referenced frequency sources, the phase noise and absolute frequency stability of these oscillators have been measured for the first time, based on both FFT-spectrum analyser and frequency-counter data. We report a double-sided phase noise of −87.5 dBc at 1 Hz, scaling as 1/f3, and a modified Allan deviation of less than 5 × 10−15 at 1 s; the fractional frequency drifts of the two oscillators with respect to the H-maser were −2.9 × 10−11 and −6.0 × 10−12 per day, respectively. Scope for further improvement is assessed.
16
A simple model of feedback oscillator noise spectrum
D.B. Leeson · Proceedings of the IEEE · 1966 · 2.4K citations
Cold atom clocks and applications
S. Bize, Ph. Laurent, Michel Abgrall et al. · Journal of Physics B Atomic Molecular and Optical Physics · 2005 · 228 citations · Full text
Subhertz-linewidth Nd:YAG laser
S. A. Webster, Mark Oxborrow, P. Gill · Optics Letters · 2004 · 97 citations