Optics Letters · 2012 · 44 citations · 13 references
Natural SciencesAstronomyOpticsSpectroscopic AnalysisSpectroscopyHyperspectral ImagingInterferometryOptical SpectroscopyPolarization OpticsPolarization-based ImagingSpectral Data ProcessingHyperspectral AnalysisPolarimetric ImagingPolarization ImagingPolarization Imaging ReconstructionPolarization InterferometryPolarization StatesSpectral Signatures
A static polarization-difference imaging spectrometer is conceptually described and demonstrated through experiment. It consists of a Wollaston prism, a Savart polariscope, a linear analyzer, and a CCD camera. This design improves the existing polarization-difference system by eliminating its moving parts and obtaining the spectral variation of the polarization state, and making the system more compact and robust. After simultaneously acquiring two sequential interference images corresponding to two orthogonal polarization states, the hyperspectral images of the states can be reconstructed, respectively. The use of uniaxial birefringent crystal can widen the detectable spectral region.
13
Review of passive imaging polarimetry for remote sensing applications
J. Scott Tyo, Dennis L. Goldstein, David B. Chenault et al. · Applied Optics · 2006 · 1.7K citations
Spectroscopy and Imaging with Diffusing Light
Arjun G. Yodh, Britton Chance · Physics Today · 1995 · 801 citations
Engineering, Biophysics, Physics +17
Imaging human epithelial properties with polarized light-scattering spectroscopy
Rajan Gurjar, Vadim Backman, Lev T. Perelman et al. · Nature Medicine · 2001 · 394 citations