Characteristics of plasma display panel with ridged dielectric and hollow gap between sustain electrodes

Mun-Ho Nam, Jungmin Kim, Sie-Young Choi, SeungHyun Son, Young‐Mo Kim

Journal of Applied Physics · 2004 · 11 citations · 7 references

Concepts

Abstract

This article presents a front panel structure for an alternating current plasma display panel (AC-PDP) based on a ridged transparent dielectric layer and long hollow gap between the sustain electrodes. The suggested structure can reduce a firing voltage and sustain voltage than a conventional AC-PDP due to a strong electric field between the sustain electrodes. Experiments were conducted with various Xe contents from 10% to 50% at a gas pressure of 450 Torr, and the results confirmed that the ridged dielectric structure reduce the firing and sustain voltages by about 74 and 79 V at 10% Xe content than a conventional structure with 10% Xe content, respectively. Also, the proposed structure improve the luminous efficiency and luminance by about 50.9% and 33%, respectively, with a 50% Xe content when compared to a conventional structure with a 10% Xe content at a similar driving voltage.

References

7