Determination of the fine-structure constant by a precise measurement of<i>h/m</i><sub>n</sub>

E. Krüger, W. Nistler, W. Weirauch

Metrologia · 1995 · 45 citations · 18 references

Concepts

Abstract

The quotient h/mn (h Planck constant, mn neutron mass) has been measured with a relative uncertainty of 7,7 × 10-8. The result is h/mn = 3,956 033 320 (302) × 10-7 m2s-1. To obtain it, a beam of neutrons with an identical and well-known wavelength was produced by Bragg reflection in a perfect silicon crystal; the velocity of the neutrons was measured using a very precise time-of-flight method. According to the de Broglie equation, h/mn is equal to the product of these two quantities. From h/mn the value of the fine-structure constant α can be derived. The measured value of h/mn leads to α-1 = 137,03601082 (524) (relative uncertainty 3,9 × 10-8). The experiment was carried out at the high-flux reactor of the Institut Laue-Langevin in Grenoble, France.

References

18