Abstract

Al exposure exceeded the FDA recommended maximum limit for all patient samples; however, the actual measured Al content of all the samples was significantly less than the calculated Al content based on manufacturer's labels. These findings suggest that manufacturers label their products with actual Al content at the time of product release rather than at time of expiration. Periodic monitoring of Al levels should be considered with prolonged PN therapy. Changes in manufacturing processes, including the use of better raw materials, are essential to reduce Al contamination to meet FDA mandates.