Journal of Biomedical Materials Research · 1985 · 160 citations · 12 references
EngineeringBioengineeringBiomedical EngineeringBiocompatibilityBiomaterialsHemostasisBiological MembranesMembrane FabricationBlood CompatibilityBlood Component CompatibilityChitosanChitosan BiomaterialsMembrane Surface ModificationSilk Biomaterials
A segment of silk polyfilament suture [No. 2-0(USP)], ca. 10 cm long, was coated with a thin membrane (2-6 micron) of chitosan, N-acetylchitosan, or N-hexanoylchitosan. The suture was directly inserted into the lumen of dog's peripheral veins. The in vivo blood compatibility of these membranes was macroscopically determined from the blood coagulum formed on the membrane surface at 2 h. An intense thick blood coagulum formed on the chitosan membrane surface and a thin blood coagulum formed on N-acetylchitosan membrane surface, but no blood coagulum formed on N-hexanoylchitosan membrane surface.
12
Selective N-acylation of chitosan
Shigehiro Hirano, Yasuo Ohe, Haruhiro Ono · Carbohydrate Research · 1976 · 267 citations
William G. Malette, H. J. Quigley, Ray D. Gaines et al. · The Annals of Thoracic Surgery · 1983 · 211 citations · Full text