Publication | Closed Access
Frequency metrology with a turnkey all-fiber system
202
Citations
9
References
2004
Year
Frequency MetrologyEngineeringOptical Transmission SystemMeasurementEducationFiber-optic CommunicationOptical PropertiesAbsolute Frequency MeasurementsHydrogen MaserInstrumentationOptical CommunicationFiber LaserPhotonicsTime MetrologyFrequency CombsFiber OpticSignal ProcessingTurnkey SystemApplied PhysicsOptoelectronics
The repetition rate and carrier-envelope phase offset frequencies of a turnkey, all-fiber-based continuum generator were phase locked to a hydrogen maser. The frequency of the hydrogen maser was calibrated with a highly stable cesium atomic clock, and therefore a fully phase-locked optical frequency comb with well-defined absolute frequencies was obtained. In contrast with the commonly used Ti:sapphire-laser-based systems, we have accomplished a fully turnkey system with no user-adjustable parts. To evaluate the performance of this novel system, we performed absolute frequency measurements in the telecommunications region and at 1064 nm and compared them with our traditional Ti:sapphire-based comb.