Journal of Biomedical Materials Research Part A · 2003 · 15 citations · 31 references
MedicineBioengineeringBiocompatibilityBiomaterialsHemostasisPlatelet ActivationPlatelet AdhesionPlatelet AggregationPlatelet FunctionPlatelet PhysiologyThrombosisAntiplatelet Therapy After Percutaneous Coronary InterventionPlatelet Activation After AdhesionPlatelet Responses To AgonistsPlatelet-rich Plasma Injection
Despite modern stent technology and effective antiplatelet therapy, metallic stents carry the risk of (sub)acute thrombosis. Our aim was to examine short-term differences in platelet deposition and coagulation activation between biodegradable polylactide (PLA), heparin-polycaprolactone-L-lactide-coated polylactide (hepa-P(CL95/L-LA5)-PLA), and stainless steel (SS) stent struts. Gel-filtered platelets (GFP) and platelet-rich plasma (PRP) were labeled with 10 nM (3)H-serotonin. Platelet deposition was measured after incubation of the stent struts in human serum albumin-coated wells at 37 degrees C in either GFP or PRP. Platelet morphology was studied by scanning electron microscopy (SEM). For coagulation activation, the stent struts were incubated in either PRP or platelet-poor plasma (PPP), anticoagulated with D-phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK), followed by measurement of fibrinogen, thrombin time (TT), prothrombin fragment 1+2 (F1+2), and thrombin-antithrombin complex (TAT). SS showed adherence of larger amounts of GFPs than did PLA at a platelet density of 300 x 10(6)/mL (p < 0.05). Furthermore, representative SEM studies showed more platelet spreading on SS than on PLA stent struts. Between PLA and SS, coagulation activity did not differ at any assessment. Based on prolonged TT values in plasma, the heparin coating strongly inhibited coagulation (p < 0.05). The values of soluble TAT and F1+2 for PLA were similar to those of controls, i.e., to incubated suspensions without a stent strut. In conclusion, when compared with stainless steel, both PLA and hepa-P(CL95/L-LA5)-PLA appear hemocompatible as intravascular stent materials.
31
Willem J. van der Giessen, A. Michael Lincoff, Robert S. Schwartz et al. · Circulation · 1996 · 853 citations · Full text
Natural Sciences, Bioengineering, Biomedical Engineering +17
Initial and 6-Month Results of Biodegradable Poly- <i>l</i> -Lactic Acid Coronary Stents in Humans
Hideo Tamai, Keiji Igaki, Eisho Kyo et al. · Circulation · 2000 · 801 citations
Medicine, Cardiology, Surgery +17
James J. Ferguson · Circulation · 1996 · 501 citations
A. Michael Lincoff, Joseph Furst, Stephen G. Ellis et al. · Journal of the American College of Cardiology · 1997 · 282 citations
Medicine, Cardiology, Pharmacology +16
Platelet-derived microparticles associate with fibrin during thrombosis
Pia Siljander, Olli Carpén, Riitta Lassila · Blood · 1996 · 152 citations · Full text
Medicine, Cell Biology, Hematology +11