EngineeringElectrical EngineeringEnergy SystemsPower ElectronicsRenewable Energy SystemsDistributed Energy ResourcesPower Electronics For Renewable EnergyPower QualityPower System StabilityPower SystemsVoltage RegulationDistributed Energy SystemsFault Ride-throughFault Ride-through CapabilityFault Ride-through ControlGrid-connected InvertersPower GenerationVoltage Ride-throughVoltage Sag Mitigation
Distributed energy resources are rapidly expanding, and their high power ratings necessitate grid codes that require robust phase‑locked loops to accurately extract grid phase under harmonic and unbalanced conditions. The study proposes fault‑ride‑through techniques using a low‑pass notch PLL and a universal six‑parameter voltage sag generator to validate low‑voltage ride‑through performance across grid codes. The LPN‑PLL delivers fast, smooth transient responses to sudden grid voltage changes and remains robust under distorted and unbalanced conditions, as demonstrated experimentally with a 10 kV·A three‑phase inverter and the sag‑generator prototype. Experimental results indicate that the LPN‑PLL enables stable operation during grid faults without tripping the system.
The amount of distributed energy resources (DERs) has constantly increased worldwide. As the power ratings of DERs have become considerably high, the grid code requirements are necessary to secure reliable power generation and transmission for the public electric network. In order to follow grid codes of the various countries and optimize the function of grid-connected inverters for DERs, a robust phase-locked loop (PLL) is essential for extracting the grid phase information accurately, when the grid voltage is polluted by harmonics and unbalanced. This paper proposes fault ride-through techniques based on a low-pass notch (LPN)-PLL. The LPN-PLL has not only fast and smooth transient responses to a sudden transition of the grid voltage but also has robustness to the distorted and unbalanced grid conditions. Therefore, the stable performance in the grid fault conditions is expected without the system trip. Furthermore, a universal voltage sag generator for the various grid codes with six parameters is proposed for the verification of low voltage ride-through (LVRT) performance. Experimental verifications are presented to show the LVRT performance based on the LPN-PLL with a three-phase grid-connected inverter (10 kV·A) and a prototype of the voltage sag generator (10 kV·A).
50