Metrologia · 1998 · 34 citations · 3 references
Radiative Heat TransferEngineeringThermal SensingRadiative Calibration AspectsThermal RadiationCalibrationHigh-heat-flux Sensor CalibrationHigh-heat-flux SensorsThermodynamicsInstrumentationHeat TransferBlack-body RadiationSensor CalibrationThermographySensorsAerospace EngineeringTemperature MeasurementThermal SensorThermal Engineering
This paper deals with the radiative calibration aspects of high-heat-flux sensors using black-body radiation. In the last two years, several heat-flux sensors were calibrated up to 50 kW/m2 using a 25 mm diameter aperture variable-temperature black body and a reference room-temperature electrical-substitution radiometer. Tests on a typical Schmidt-Boelter heat-flux sensor showed long-term repeatability of calibration is within 0.6%. Plans for extending the present calibration capability to 100 kW/m2 are discussed.
3
Two Blackbody Radiometers of High Accuracy
J. M. Kendall, C. M. Berdahl · Applied Optics · 1970 · 93 citations