Applied Optics · 2010 · 37 citations · 17 references
EngineeringEarth SciencesAtmospheric ScienceRadiation DetectionRadiation MeasurementCalibrationEquipment CalibrationRadiation InstrumentationRadiometric CalibrationSensor CalibrationTemperature MeasurementBlackbody CalibrationBlackbody RadiationEmissivityRadiance CalibrationRadiometer CalibrationTemporal StabilityTemporal Stability AnalysisTemporal Stability Assessment
We analyze two important points related to the experimental emissivity measurements in this paper: the radiometer calibration accuracy and its stability to determine the required frequency of calibration. The usual two-temperature calibration method is compared to a more accurate method, which uses the measurement of blackbody radiation at several temperatures. Additionally, the suitability of the two-temperature method is studied as a function of the gap between both temperatures. Differences higher than 200°C are needed to obtain an acceptable calibration. The temporal stability of the calibration and the influence of the environmental conditions are also analyzed.
17