Journal of Micromechanics and Microengineering · 2008 · 20 citations · 13 references
EngineeringMaterials EngineeringMaterials ScienceMicroelectromechanical SystemsMicrofabricationThin FilmsMems ActuatorsMems MaterialsMems TestingMicroelectromechanical SensorsPiezoelectric ActuatorsPiezoelectric MaterialsElectromechanical CouplingFatigue MechanismsFatigue Testing Of Mems DevicesLead Zirconate TitanateMechanical Testing Of Mems DevicesMicrocantilever SensorsPiezoelectric SensorsPiezoelectric Thin Films
In the present study, we propose a new method for the fatigue test of lead zirconate titanate (PZT) thin films for MEMS devices by using self-sensitive piezoelectric microcantilevers developed in our previous study. We have deposited PZT thin films on SOI wafers and fabricated the microcantilevers through the MEMS microfabrication process. In the self-sensitive piezoelectric microcantilevers, the PZT thin films are separated in order to act as an actuator and a sensor. The fatigue characteristic of the PZT thin films can be evaluated by measuring the output voltage of the sensor as a function of time. When a sine wave of 20 Vpp and a dc bias of 10 V were applied to the PZT thin films for an actuator, the output voltage of the sensor fell down after 107 fatigue cycles. We have also investigated the influence of amplitude of the actuation sine wave and dc bias on the fatigue of the PZT thin films by using the proposed fatigue test method.
13