IEEE Photonics Technology Letters · 1989 · 15 citations · 6 references
Natural SciencesPhysicsOpticsPhotonicsPlasma PhysicsX-ray OpticsX-ray SpectroscopyElectron Beam GenerationFlashoverHigh-power LasersPenetration DepthPlasma X-ray SourcesSpecific Energy
The first experimental results are presented of an X-ray preionized argon-buffered xenon laser. The X-rays are generated by a simple electron-beam device located below the 23-cm inner diameter laser chamber. The advantages of X-ray preionization for high-pressure discharge-pumped lasers include the long X-ray penetration depth, high preionization density, and spatial uniformity. The combination of X-ray preionization and techniques to eliminate surface flashover allows energetic operation in 4 atm of argon buffer for the first time in a photopreionized discharge laser. The argon-xenon mixtures lased primarily at 1.73 mu m and 2.63 mu m with a peak energy of 340 mJ at 4 atm, and a specific energy output of 0.85 J/liter.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6
The high-pressure neutral infrared xenon laser
S. A. Lawton, J.B. Richards, Leon Newman et al. · Journal of Applied Physics · 1979 · 84 citations
Natural Sciences, Physics, Optics +16
60 J quasistationary electroionization laser on Xe atomic metastables
N G Basov, V.V. Baranov, A Yu Chugunov et al. · IEEE Journal of Quantum Electronics · 1985 · 51 citations
Natural Sciences, Physics, Optics +11
Electron-beam-controlled atomic Xe infrared laser
N G Basov, V. A. Danilychev, A Yu Dudin et al. · Soviet Journal of Quantum Electronics · 1984 · 39 citations